Approximate maximum wattage on a 16A circuit at 230V?· ~1920W✓ ~3680W· ~7360W· ~960WP = V × I = 230 × 16 ≈ 3680W. At 120V the same 16A gives only ~1920W.
"SWL" / "WLL" on a truss or clamp refers to…· The breaking load✓ The safe / working load limit· The unit's weight· Beam angleSafe/Working Load Limit is the rated maximum to use — far below the breaking load, with a safety factor built in.
On a three-phase supply you should…· Put everything on L1✓ Balance load across L1/L2/L3· Ignore phase entirely· Only use neutralSpreading load evenly across the three phases avoids overloading one and tripping it.
Every overhead fixture additionally requires…· A second gel frame✓ A safety bond / secondary suspension· A spare lamp taped on· Two power feedsA safety bond rated for the fixture mass is a legal and practical must if the primary clamp fails.
A DMX data line should be terminated at the last device with…✓ A 120Ω terminator· A power plug· An open end· A mic capsuleA 120Ω terminator on the final unit prevents signal reflections that corrupt the data.
Why leave headroom rather than load a circuit to 100%?· It looks tidy✓ Inrush, heat and safety margin· To save gel· DMX requires itLamp inrush current, heat and a safety margin mean you never run a circuit right at its rated maximum.